    F5 BIG-IP High Availability Failover Playbook

    Active unit failed, config sync issues, floating IP problems, and split-brain scenarios. F5 HA failovers should be transparent but often cause 10-30 seconds of connection drops. When failover fails, you're running on a single unit with no redundancy - or worse, both units think they're active.

    Operator's Field Notes

    Jeremy Martinez · Incident Commander | Principal Site Reliability Engineer

    "F5 HA failovers are one of those things that work perfectly in testing and then cause a 15-minute outage in production. The most common issue: config sync is out of date. The standby unit takes over with stale configuration - missing pools, wrong iRules, expired certificates. Always verify config sync status before you need to fail over."

    "The scariest scenario is split-brain: both units think they're active and both are answering ARP requests for the floating IPs. Traffic bounces between them randomly. You'll see intermittent failures that look like a network issue. Check tmsh show cm failover-statuson BOTH units - if both say 'active', you have a split-brain and you need to force one standby immediately."

    First 5 Minutes - Triage

    1. Check HA Status on Both Units

    # On BOTH units - compare results
    tmsh show cm failover-status
    # Should show: "active" on one, "standby" on the other
    
    # Check device trust
    tmsh show cm device-group
    tmsh show cm sync-status
    
    # Check if config sync is current
    tmsh show cm sync-status detail
    # "In Sync" = good
    # "Changes Pending" = standby has stale config
    # "Disconnected" = HA communication broken
    
    # Check failover state history
    tmsh show sys failover
    cat /var/log/ltm | grep -i "failover"

    2. Check HA Communication

    # Check failover unicast addresses
    tmsh list cm device | grep unicast
    
    # Check network failover connectivity
    tmsh show net interface | grep HA
    
    # Check failover cable (if using serial failover)
    tmsh show sys failover | grep serial
    
    # Ping the peer's management and HA addresses
    ping PEER_MGMT_IP
    ping PEER_HA_IP
    
    # Check for network issues between units
    tmsh run util traceroute PEER_HA_IP

    3. Check Floating IPs (Traffic Groups)

    # Check which unit owns the floating IPs
    tmsh show cm traffic-group traffic-group-1
    
    # Verify floating IPs are responding
    tmsh show net self
    tmsh show net arp
    
    # Check if ARP is correct for floating IPs
    # From a connected switch or router, verify MAC address
    # matches the currently active unit

    Recovery Procedures

    Force Failover to Standby

    # Force failover (run on the CURRENTLY ACTIVE unit)
    tmsh run sys failover standby
    
    # Force a specific unit to be active
    # (run on the unit you want to be active)
    tmsh run sys failover active
    
    # If GUI is available:
    # System → High Availability → Force to Standby State
    
    # CRITICAL: Before forcing failover, verify config sync!
    tmsh show cm sync-status
    # If not in sync, sync first:
    tmsh run cm config-sync to-group my-device-group

    Fix Split-Brain

    # SPLIT-BRAIN: Both units think they're active
    # This is URGENT - causes intermittent traffic failures
    
    # 1. Choose which unit should be active (usually the one with newer config)
    # 2. Force the OTHER unit to standby:
    tmsh run sys failover standby    # Run on the unit that should be STANDBY
    
    # 3. Verify HA communication is restored
    tmsh show cm failover-status     # Run on both
    
    # 4. If HA communication is broken:
    # - Check failover network (cable, VLAN, IPs)
    # - Restart failoverd daemon
    tmsh restart sys service failoverd
    
    # 5. Resync configuration
    tmsh run cm config-sync to-group my-device-group

    Sync Configuration

    # Push config from active to device group
    tmsh run cm config-sync to-group my-device-group
    
    # If sync fails, check for conflicts
    tmsh show cm sync-status detail
    
    # Force overwrite standby config (destructive to standby changes)
    tmsh run cm config-sync force-full-load-push to-group my-device-group
    
    # If all else fails, export UCS from active and import on standby
    # On active:
    tmsh save sys ucs /var/tmp/backup.ucs
    # Copy to standby
    # On standby:
    tmsh load sys ucs /var/tmp/backup.ucs no-license

    Connection Mirroring

    Connection mirroring replicates connection table to standby. Without it, all active connections are dropped on failover.

    # Check mirroring status
    tmsh show sys connection mirror
    
    # Enable mirroring on virtual server
    tmsh modify ltm virtual my-app-vs mirror enabled
    
    # Check mirror port configuration
    tmsh list cm device | grep mirror
    
    # Note: Mirroring adds overhead - only enable for long-lived connections
    # (WebSockets, database proxies, etc.)
    # Short-lived HTTP requests typically don't need mirroring

    Prevention

    HA Maintenance

    • • Verify config sync after every change
    • • Test failover quarterly (planned)
    • • Monitor sync status via SNMP
    • • Keep firmware versions matched
    • • Separate HA VLAN from production traffic

    Monitoring

    • • Alert on failover events (syslog/SNMP)
    • • Monitor config sync drift
    • • Track connection count on both units
    • • Certificate expiration monitoring
    • • Regular UCS backup schedule